ASSA ABLOY - Specification Manual

assaabloy.com 147 Panic and emergency hardware Legislation Emergency hardware classification key Panic hardware classification key Grading scope Grading scope EN 1125:2008 EN 179:2008 CATEGORY OF USE Determines the frequency of use of the product. Grade 3: Suitable for high frequency use by users with little incentive to treat hardware carefully (3) CATEGORY OF USE Determines the frequency of use of the product. Grade 3: Suitable for high frequency use by users with little incentive to treat hardware carefully (3) FIRE BEHAVIOUR AND RESISTANCE Suitability of product use on fire/smoke door assemblies having successfully met EN 1634-1 legislation. Grade 0: Not suitable for fire/smoke door assemblies Grade A: Suitable for smoke door assemblies Grade B: Suitable for use on smoke and fire doors (0/A/B) FIRE BEHAVIOUR AND RESISTANCE Suitability of product use on fire/smoke door assemblies having successfully met EN 1634-1 legislation. Grade 0: Not suitable for fire/smoke door assemblies Grade A: Suitable for smoke door assemblies Grade B: Suitable for use on smoke and fire doors (0/A/B) CORROSION RESISTANCE Corrosion resistance to EN 1670 Neutral Salt Spray test and operation of the product at extreme temperatures. Grade 3: High resistance 96 hours salt spray at -20°C to +80°C Grade 4: Very high resistance 240 hours hour salt spray test at -20°C to +80°C (3-4) CORROSION RESISTANCE Corrosion resistance to EN 1670 Neutral Salt Spray test and operation of the product at extreme temperatures. Grade 3: High resistance 96 hours salt spray at -20°C to +80°C Grade 4: Very high resistance 240 hours hour salt spray test at -20°C to +80°C (3-4) SECURITY Tests the ability to release under side load. The principle concern for panic device performance is safety over security. Grade 2: Up to 1000N (2) SECURITY Tests the ability to release under side load. The principle concern for panic device performance is safety over security. Grade 2: Up to 1000N Grade 3: Up to 2000N Grade 4: Up to 3000N Grade 5: Up to 5000N (2-5) (6-7) NUMBER OF TEST CYCLES Tests the durability of the product through various cycle tests. Grade 6: 100,000 test cycles Grade 7: 200,000 test cycles (6-7) NUMBER OF TEST CYCLES Tests the durability of the product through various cycle tests. Grade 6: 100,000 test cycles Grade 7: 200,000 test cycles TEST DOOR MASS/SIZE Takes into account the mass of the door which the hardware product can reliably be used on. Grade 5: Doors up to 100KG Grade 6: Doors up to 200KG Grade 7: Doors over 200KG (5-7) TEST DOOR MASS/SIZE Takes into account the mass of the door which the hardware product can reliably be used on. Grade 5: Doors up to 100KG Grade 6: Doors up to 200KG Grade 7: Doors over 200KG (5-7) PROJECTION OF DEVICE Classifies how far the opening mechanism projects from the door face. This can be either large or standard projection. Class 1 - Projection up to 150mm Class 2 - Projection up to 100mm PROJECTION OF DEVICE Classifies how far the opening mechanism projects from the door face. This can be either large or standard projection. Class 1 - Projection up to 150mm Class 2 - Projection up to 100mm (1-2) TYPE OF DEVICE (see ‘Digit 9 – device operation’ on diagram overleaf) Identifies the type of operation. EN 1125 and EN 179 have specific operating types which are further categorised by device type. Type A - ‘push bar’ operation Type B - ‘touch bar’ operation (A/B) TYPE OF DEVICE (see ‘Digit 9 – device operation’ on diagram overleaf) Identifies the type of operation. EN 1125 and EN 179 have specific operating types which are further categorised by device type. Type A - ‘lever handle’ operation Type B - ‘push pad’ operation (A/B) SAFETY Categorises the level of safety for the product. Grade 1: All panic and emergency exit devices have a critical safety function, therefore only one grade is classified (1) SAFETY Categorises the level of safety for the product. Grade 1: All panic and emergency exit devices have a critical safety function, therefore only one grade is classified (1) FIELD OF APPLICATION Confirms the door configuration which the unit will satisfy. Class A - outward opening single/double doors with active/inactive leaf Class B - outward opening single door only Class C - outward opening double exit door with inactive leaf only (A-C) FIELD OF APPLICATION Confirms the door configuration which the unit will satisfy. Class A - outward opening single/double doors with active/inactive leaf Class B - outward opening single door only Class C - outward opening double exit door with inactive leaf only Class D - Inward opening single door only (A-D) (1-2)

RkJQdWJsaXNoZXIy NTI5NzM=