ASSA ABLOY - Specification Manual

assaabloy.com 19 Door controls Introduction Parts of a door closer Trim plate Rack and pinion arm Guide rail Cover Parallel arm bracket Is it a fire door? To ensure a door closer is suitable for the door type, it is important to understand its scope of certification. Our fire test certification is clearly indicated to illustrate its suitability across timber and metal doors, tests range from 30 to 240 minutes and detail all suitable fixing configurations. For concealed units intumescent kit details are also stated. What is the door width and weight? The width and weight of the door dictates what door closer size needs to be used, each closer is tested to comply with the standard EN 1154 to ensure safety and functionality on all doors. Please see table below: DC power size Max door width Max door weight EN 1 750mm 20kg EN 2 850mm 40kg EN 3* 950mm 60kg EN 4 1100mm 80kg EN 5 1250mm 100kg EN 6 1400mm 120kg EN 7 1600mm 160kg *Remember, EN 3 is the minimum requirement for a fire door. Which way does the door open? What is the direction of operation – are you pulling or pushing the door to open it? Our fire test certification ensures fixing configurations are clearly highlighted to ensure suitability and coverage on both leaf and frame head (transom) mounting applications. Considerations for selecting the right door control