assaabloy.com 719 Specification Holding force 900/900M - 600kg, 910/910M - 700kg, 911/911M - 1,000kg, 920/920M - 1,000kg Use 900/900M - Interior only, 910/910M - Interior and entrance doors 911/911M - Interior and entrance doors, 920/920M - Interior and entrance doors Operating temperature -20°C to + 60°C Current draw 250mA @12Vdc – 130mA @24Vdc Voltage tolerance 12 – 24v DC Solenoid Rated for continuous use Monitoring Latchbolt engagement monitoring Duty 900/900M - fail safe or fail secure selectable, 910/910M - fail secure only 911/911M - fail safe only, 920/920M - fail secure only Tested to 1,000,000 cycles Dimensions (H x W x D) case 140 x 26.5 x 37.5mm Mechanism Steel Faceplate finish SS Latch Suitable for 15mm latch with 3mm door gap Accessories See electromagnetic accessories section for items such as faceplates UKCA / CE marked (fire) Yes UKCA / CE marked (EMC) Yes Certified in compliance with EN 61000-6-1, EN 61000-6-3, EN 14846 (920&920M only) Suitable for fire doors Yes (920&920M only) Guarantee 5 years 900, 910, 911 and 920 series High strength electric strikes ideal for doors with standard security requirements. Stainless steel housing and steel pivoting staple offers greater protection and resistance to attack Impact and shock proof design (910, 911 and 920), provides higher security and integrity to the doors locking mechanism Pre-load (910, 911 and 920) allows doors to continue to operate despite pressures exerted by door seals, air flow and misaligned doors Works in both 12 and 24v DC Optional latchbolt engagement monitoring Built-in transient protection against back electric and magnetic fields EMF, prevents damage to electronics from voltage spikes Symmetrical design to fit Scandinavian double latch locks Compatible with Modular and Connect range lockcases Testing and certification Dimensions Order code Description Finish 900107000 900 strike body 12/24V multifunction SS 900437000 900M strike body 12/24V multifunction – monitored SS 910107000 910 strike body 12/24V fail secure SS 910437000 910M strike body 12/24V fail secure – monitored SS 911107000 911 strike body 12/24V fail safe SS 911437000 911M strike body 12/24V fail safe – monitored SS 920107000 920 strike body 12/24V fail secure SS 920437000 920M strike body 12/24V fail secure – monitored SS How to order Features and benefits 3 3 X x 9 9 D D - - 0 0 0 0 1 1 0 1 (1-3) (1-3) (A-Y) (A-Y) (1-9) (1-9) (0-F) (0-F) (NPD) (NPD) (0-P) (0-P) (0-7) (0-7) (0-3) (0-3) (0-1) (0-1) EN 14846:2008 EN 14846:2008 Standard Monitored Classification code Electromechanical locking Electric strikes P.82 900, 910, 911 and 920 series 140 44 23 37.5 26.5
RkJQdWJsaXNoZXIy NTI5NzM=