ASSA ABLOY - Specification Manual

assaabloy.com 773 Specification Use Interior and entrance doors Operational temperature -20ºC to +70ºC Current draw 50 mA at idle 445 mA at 24v DC Voltage tolerance 12 or 24V DC Monitoring Dead latching, error, door forced, door status indication Duty Fail safe or fail secure selectable Tested to 1,500,000 cycles Backset 50mm Dimensions (H x W x D) case 150 x 20 x 71mm Dimensions (H x W x D) faceplate 225 x 22 x 3mm Mechanism Stainless steel Door gap 3mm +/-1mm Finish SS Accessories N/A UKCA / CE marked (fire) Yes UKCA / CE marked (EMC) Yes Certified in compliance with SSF 3522-1093 class 1, EN 14846 Suitable for fire doors Yes Guarantee 1 year Handle-controlled motor lock – 813C-50 Electromechanical lockcase with deadlatch. Deadlatching handles on both sides are electronically activated by a signal from the access control system, code lock or similar; alternatively, the inside handle can be activated by a request to exit button. Electronically controlled inside and outside (fixed spindle) Lock can be adjusted for right or left hung doors Lock can be opened with a key or thumb turn Includes reversible deadlatch Can be adjusted to work as 815C-50 Status indication on the Hi-O bus and via relay on I/O BOX Testing and certification Dimensions Order code Description Finish 705198127031 813C-50 complete kit SS 705198117031 813C-50 ARX kit SS 705198107031 813C-50 lock housing only SS How to order Features and benefits 1 Electromechanical locking Electric mortice locks 3 X L 8 F - 1 1 3 (1-3) (A-Y) (1-9) (0-F) (NPD) (0-P) (0-7) (0-3) (0-1) EN 14846:2008 Classification code P.136 Handle-controlled solenoid lock – 813C-50 19.8 14 225 74 22 3 150 105 19.5 37.5 203 11 50

RkJQdWJsaXNoZXIy NTI5NzM=