Jointing Tech - Rail Catalogue

MV Terminations Inner Cone Terminations www.jointingtech.co.uk 32 Part number Description Info For use with cone size 827-150-005 Dummy Cable Connector For Sealing And Voltage Proof Closing Of Connex Connectors Size 0 827-150-002 Dummy Cable Connector For Sealing And Voltage Proof Closing Of Connex Connectors Size 1 827-150-003 Dummy Cable Connector For Sealing And Voltage Proof Closing Of Connex Connectors Size 2 827-150-004 Dummy Cable Connector For Sealing And Voltage Proof Closing Of Connex Connectors Size 3 827-134-004 Protecting Cap For Protecting Withdrawn Connex Connectors Against Dirt Size 0 827-134-001 Protecting Cap For Protecting Withdrawn Connex Connectors Against Dirt Size 1 827-134-002 Protecting Cap For Protecting Withdrawn Connex Connectors Against Dirt Size 2 827-134-003 Protecting Cap For Protecting Withdrawn Connex Connectors Against Dirt Size 3 Cone Size Part number Max Voltage Max Current Cross Section Dia Core Insulation Voltage Tap SIZE 0 870-01X-XXX 12kV 250A 25-70mm² 12.0mm - 19.2mm NO SIZE 0 870-02X-XXX 24kV 250A 25-50mm² 15.0mm - 23.5mm NO SIZE 1 870-11X-XXX 12kV 630A 35 - 240mm² 14.8mm - 28.4mm NO SIZE 1 870-12X-XXX 24kV 630A 35 - 240mm² 19.0mm - 32.6mm NO SIZE 1 870-13X-XXX 36kV 630A 50 - 150mm² 25.2mm - 33.5mm NO SIZE 1 850-11X-XXX 12kV 630A 35 - 240mm² 14.8mm - 28.4mm YES SIZE 1 850-12X-XXX 24kV 630A 35 - 240mm² 19.0mm - 32.6mm YES SIZE 1 850-13X-XXX 36kV 630A 50 - 150mm² 25.2mm - 33.5mm YES SIZE 2 870-21X-XXX 12kV 800A 95 - 300mm² 13.7mm - 30.4mm NO SIZE 2 870-22X-XXX 24kV 800A 50 - 300mm² 20.2mm - 34.6mm NO SIZE 2 870-23X-XXX 36kV 800A 50 - 300mm² 16.0mm - 38.0mm NO SIZE 2 850-21X-XXX 12kV 800A 95 - 300mm² 13.7mm - 30.4mm YES SIZE 2 850-22X-XXX 24kV 800A 50 - 300mm² 20.2mm - 34.6mm YES SIZE 2 850-23X-XXX 36kV 800A 50 - 300mm² 16.0mm - 38.0mm YES SIZE 3 870-31X-XXX 12kV 1250A 240 - 630mm² 26.5mm - 39.6mm NO SIZE 3 870-32X-XXX 24kV 1250A 150 - 630mm² 26.5mm - 45.6mm NO SIZE 3 870-33X-XXX 36kV 1250A 95 - 630mm² 28.5mm - 50.0mm NO SIZE 3 850-31X-XXX 12kV 1250A 240 - 630mm² 26.5mm - 39.6mm YES SIZE 3 850-32X-XXX 24kV 1250A 150 - 630mm² 26.5mm - 45.6mm YES SIZE 3 850-33X-XXX 36kV 1250A 95 - 500mm² 28.5mm - 50.0mm YES SIZE 3S 850-350-XXX 52kV 1250A 120 - 630mm² 32.0mm - 50.0mm NO Connex Plug in System for size 0, 1, 2 & 3 FEATURES ■ The “Plug In” connector employs an insulated silicone bushing to control the ■ Heat shrinkable sleeve provides a moisture barrier between the cable sheath and the alloy housing of the connector ■ The termination is completed by plugging into the equipment and taking the cable screen to earth ■ Sold in sets of three phases ■ Installation tooling available to buy ■ Training courses available ■ Designed to meet the requirements of EN 50180, 50181, DIN 47637 and are suitable for all cables to IEC 502 with graphite coated, bonded or “Easy Peel” semiconducting screens

RkJQdWJsaXNoZXIy NTI5NzM=